AT600 User’s Manual 135
Chapter 5. Communication
Command 218 (0xDA): Write Reynolds KFactor Table
This command is to write Reynolds KFactor table.
Table 150: Request Data Bytes for Write Reynolds KFactor Table
Byte Format Description
0 Unsigned-8 Reynolds KFactor Index ( 1 - 6 )
1 – 4 Float Reynolds Value
5 – 8 Float Reynolds KV Value;
Table 151: Response Data Bytes for Write Reynolds KFactor Table
Byte Format Description
0 Unsigned-8 Reynolds KFactor Index ( 1 - 6 )
1 – 4 Float Reynolds Value
5 – 8 Float Reynolds KV Value;
Table 152: Command-Specific Response Codes for Write Reynolds KFactor Table
Code Class Description
0 Success No Command-Specific Errors
1Undefined
2 Error Invalid Selection
3-4 Undefined
5 Error Too Few Data Bytes Received
6 Error Device-Specific Command Error
7Error In Write Protect Mode
8-15 Undefined
16 Error Access Restricted
17-127 Undefined