GDS3710 User Manual
Version 1.0.7.8
Tamper Alarm
Tamper alarm is anti-hack from Hardware level. When this option is checked, if the GDS3710 is removed
from the installation board, it will trigger configured alarm actions. There is an embedded mechanism on
the GDS3710 that allows it to detect when it is removed.
Table 26: Tamper Alarm
When activating this mode, GDS3710 will keep alarming until the alarm
is dismissed.
Select Alarm Action Profile
Select the type of alarms actions to be triggered for the tamper alarm
mode.
Keypad Input Error Alarm
Table 27: Keypad Input Error Alarm
Enable Keypad Input Error
Alarm
Enable/Disable the Input Error Alarm, GDS3710 will trigger alarm
actions at every 5 incorrect attempts.
Select Alarm Action Profile
Select the type of alarms actions to be triggered after 5 incorrect
attempts.
Non-Scheduled Access Alarm
Table 28 : Non-Scheduled Access Alarm
Enable Non-Scheduled
Access Alarm
When enabling this feature, GDS3710 will trigger alarm to related
administrator to be aware when legitimated users access the door out
of the allowed configured schedule
Select Alarm Action Profile
Select the type of alarms actions to be triggered.
Alarm Schedule Settings
This page specifies the configuration of Alarm Schedule.
Note: Schedule must be configured first to allow the alarm to take the related action.