Table 6: Door System Settings
This option allows to choose to use Alarm_Out (COM1) interface for either
as alarm out with 3
rd
party device, or to control a second door “Door 2”
(the two functions are mutual exclusive).
When option “Open Door” is selected, will enable GDS3710 to control the
operation of two doors via RFID, local and remote PINs.
Select Normal Open or Normal Close depending on the lock used.
Device will open door after specified delay (in seconds) when user issuing
the authorization.
Configures the lock holding time, in seconds (default value is 5 seconds).
Device will hold the door unlocked for this specified duration.
Range: 1-20 seconds.
Minimum Interval of
Swiping Card (ms)
Defines the interval in ms to swipe consecutive RFID cards. The range
should be between 0ms and 2000ms.
Number of Snapshots
when Door Opened
Define number of snapshot to be sent by the GDS ( vie FTP or Email)
Maximum up to 4 screenshots.
Snapshot when Door
Opened
User can choose to email the snapshot when door is opened without
sending the snapshots via FTP to the FTP server.
Snapshot when Doorbell
Pressed
User can choose to email the snapshot when doorbell pressed without
sending the snapshots via FTP to the FTP server.
Chooses whether to make call to the SIP number or Virtual Number when
dialing from the GDS3710 keypad.
Doorbell Call Out Account
This option sets the account to be used to make call upon the
doorbell trigger. If set to Auto, the GDS will use the first available account.
Configures the action to be taken when the doorbell is pressed, three
options are available:
• Call Doorbell Number: when Doorbell is pressed, a call will be
made to the “Number Called When Door Bell Pressed”
• Control Doorbell Output (Digital Output 1): when Door Bell is
pressed electronic lock for Output 1 is opened.
• Both of Above: When selected, both Call Doorbell Number and
Control Doorbell Output options are enabled.