Configures the key tones for the GDS3710.
• Default: Beeps will be played when pressing the GDS3710 keys.
• DTMF: Tones will be played when pressing the GDS3710 keys.
• Mute: No sound will be played when pressing keys.
Notes: Remote SIP phone needs password (digits 0-9 only, ended with # key) matching the configuration
on the web page to open the door (via DTMF).
GDS3710 support RFID for multiple users to open door, therefore every user has its own PIN. For
environment with large number of users (limit is 2000), it’s difficult for the GDS3710 to manage all these
users, so a separate PC or Server should be involved for such kind of management and monitoring.
In environments with large number of users (limit is 2000), the GDS3710, another possibility would be to
set one unified Local PIN for opening the door for all the users.
Using Alarm Out (COM 1) to Control a Second Door
Starting from firmware 1.0.5.2, user can now set Alarm_Out (COM1) interface to control a second Door, in
additional to the existing Locker/COM2 interface (controlling Door1).
This feature allows GDS3710 to control the operation of two doors via RFID, local and remote PINs.
For example, a 3
rd
party Wiegand Input device or GDS3710 can be installed at Door2 with related cable
wired into the control GDS3710 installed at Door1. The Door1 and Door2 can be configured to be open by
programmed RFID cards, PINs either separately or both.