2-35
Reference Pen Conditions for Plotting Pen
Pen type Part no. Cut/Force Speed (cm/s) Acceleration
Water-based ber-tip pen KF700 series 10 to 12 30 2
Oil-based ballpoint pen KB700-BK 12 to 31 60 2
To prolong the pen life, set the FORCE to the lowest setting, and set the SPEED after checking to conrm that
there are no faint lines or other problems during plotting.
Supplement
•
Finish will become coarser, but the cut time is decreased when the settings for the speed and acceleration is set higher.
Especially with the large media, good cut quality might not be achieved by rumbling media. Decrease the values for the speed and
acceleration settings in that case.
•
Finish will become good, but the cut time will increase when the settings for the speed and acceleration is set smaller.