FC4200-UM-251-03-9370 51
ELECTRICAL SECTION
7.16 Setting the Power Unitʼs Supply Voltage
(1) Check that the plotterʼs POWER switch is off.
(2) Open the chassis of the Main Control Box.
Power Unit
(3) Connect the power unitʼs cable to the required connector.
Voltage series Corresponding area Connector
100 V JAP 110T/K WGl117UL CN2
200 V CEE SEV BS AS CN3