154
Interface Configuration
USB Remote Interface Optional (APS-7050 and APS-7100
only)
USB
configuration
PC side
connector
Type A, host
APS-7000 side
connector
Rear panel Type B, slave
Speed
1.1/2.0 (full speed/auto speed)
USB Class
CDC (communications device
class)
Note
The RS-232/USB interface card (APS-002) must
first be installed before the USB interface can be
used for remote control. Please see page 41 for
installation details.
Steps
1. Connect the Type A-Type B USB
cable from the PC to the rear
panel USB B port.
2. Press the Menu key. The Menu
setting will appear on the display.
Menu
3. Use the scroll wheel to go to item 6, Rear USB
and press Enter.
4. Go to the Speed setting and set the USB speed.
Speed
Full, Auto
5. If the connection is successful Connection Status
will change from Offline to Online.