OPERATION
85
Ramp Control
The Ramp Control function controls how fast the voltage level
ramps up and down. This function allows you to ramp the voltage
as a unit of time or as a unit of voltage.
Parameter
Settings
Time
The Time setting allows you to set
the ramp time as ms/Vrms.
Tup = ramp up time/1Vrms
Tdn = ramp down time/1Vrms
1Vrms 1Vrms
Tup Tdn
Voltage
The Voltage setting allows you to set
the ramp time as Vrms/ms.
Vup = voltage up/1ms
Vdn = voltage down/1ms
Vup Vdn
1ms 1ms
Steps
1. Press the Menu key. The Menu
setting will appear on the display.
Menu
2. Use the scroll wheel to go to item 3, Ramp
Control and press Enter. Alternatively, use the
short-cut key shift+5.