APPENDIX
179
APS-7000 Default Settings
The following default settings are the factory configuration settings
for the power supply.
For details on how to return to the factory default settings, see page
54.
Continuous Mode
APS-7050
APS-7100
APS-7200
APS-7300
Range
155V
ACV
0.00V
FREQ
60.00Hz
IRMS
4.20A
8.40A
16.80A
25.20A
ON PHS
OFF PHS
V limit
155.0Vrms
F Limit
500.0Hz
Ipeak Limit
16.80A
33.60A
67.20A
100.8A
Simulation Mode
APS-7050
APS-7100
APS-7200
APS-7300
Step
Initial
Repeat
1
Time
0.10s
ON Phs
ON, 0
Vset
0.00
OFF Phs
ON, 0
Fset
50.00
Trig Out
LO
Range
HI
Sequence Mode
APS-7050
APS-7100
APS-7200
APS-7300
Step
0
Time
0.10s
Jump To
ON, 1
Jump Cnt
1
Branch1
OFF
Branch2
OFF
Term
CONTI
Trig Out
LO