8. The terminal display will return the following:
GWINSTEK,APS-7050, GEXXXXXXX,
XX.XX.XXXXXXXX
(manufacturer, model, serial number, software
version)
9. If Realterm fails to connect to the APS-7000,
please check all the cables and settings and try
again.
Configure GPIB Interface - Optional
To use GPIB, the optional APS-001 GPIB interface card must first be
installed.
Note
The GPIB interface card (APS-001) must first be
installed before the GPIB interface can be used for
remote control. Please see page 41 for installation
details.
GPIB
Configuration
1. Connect a GPIB cable from the
PC to the GPIB on the interface
card.
GPIB
2. Press the Menu key. The Menu
setting will appear on the display.
Menu
3. Use the scroll wheel to go to item 8, GPIB and
press Enter.
4. If the GPIB card is installed successfully, the
Card Status will show Plugged in.
5. Go to the Function Active setting and turn the
GPIB port on.

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals