280
• The maximum response delay for MLD general queries is set by the max-response-time command.
• The maximum response delay for MLD multicast-address-specific queries equals the MLD
last-listener query interval.
Configuring MLD queries and responses globally
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter MLD-snooping view.
mld-snooping N/A
3. Set the maximum response
delay for MLD general
queries.
max-response-time interval 10 seconds by default
4. Set the MLD last-member
query interval.
last-listener-query-interval interval
1 second by default
Configuring the parameters for MLD queries and responses in a VLAN
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VLAN view.
vlan vlan-id N/A
3. Set the MLD query interval.
mld-snooping query-interval
interval
125 seconds by default
4. Set the maximum response
delay for MLD general
queries.
mld-snooping max-response-time
interval
10 seconds by default
5. Set the MLD last-member
query interval.
mld-snooping
last-listener-query-interval interval
1 second by default
Configuring the source IPv6 addresses for MLD queries
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VLAN view.
vlan vlan-id N/A
3. Configure the source IPv6
address of MLD general
queries.
mld-snooping general-query
source-ip { ipv6-address |
current-interface }
FE80::02FF:FFFF:FE00:0001 by
default
4. Configure the source IPv6
address of MLD
multicast-address-specific
queries.
mld-snooping special-query
source-ip { ipv6-address |
current-interface }
FE80::02FF:FFFF:FE00:0001 by
default
IMPORTANT: