281
Configuring MLD snooping proxying
Before you configure MLD snooping proxying in a VLAN, complete the following tasks:
• Enable MLD snooping in the VLAN.
• Determine the source IPv6 address for the MLD reports sent by the proxy.
• Determine the source IPv6 address for the MLD done messages sent by the proxy.
Enabling MLD snooping proxying
The MLD snooping proxying function works on a per-VLAN basis. After you enable the function in a
VLAN, the device works as the MLD snooping proxy for the downstream hosts and upstream router in the
VLAN.
To enable MLD snooping proxying in a VLAN:
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VLAN view.
vlan vlan-id N/A
3. Enable MLD snooping
proxying in the VLAN.
mld-snooping proxying enable Disabled by default
Configuring the source IPv6 addresses for the MLD messages
sent by the proxy
You can set the source IPv6 addresses for the MLD reports and done messages that the MLD snooping
proxy sends on behalf of its attached hosts.
To configure the source IPv6 addresses for the MLD messages that the MLD snooping proxy sends in a
VLAN:
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VLAN view.
vlan vlan-id N/A
3. Configure a source IPv6
address for the MLD
reports that the proxy
sends.
mld-snooping report source-ip
{ ipv6-address | current-interface }
The default is
FE80::02FF:FFFF:FE00:0001.
4. Configure a source IPv6
address for the MLD
done messages that the
proxy sends.
mld-snooping done source-ip
{ ipv6-address | current-interface }
The default is
FE80::02FF:FFFF:FE00:0001.