EasyManuals Logo

Hirschmann MACH 4000 Reference Manual

Hirschmann MACH 4000
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
Switching
92
4.1
Switching Global
RM Web
Release
6.0
07/2010
X Collisions, late collisions: In full-duplex mode, the port does not count
collisions or late collisions.
X CRC error: The device only evaluates these errors as duplex problems in
the manual full duplex mode.
No. Autonegotiati
on
Current
duplex
mode
Detected error
events ( 10)
Evaluation of
duplex
situation by
device
Possible causes
1 On Half duplex None OK
2 On Half duplex Collisions OK
3 On Half duplex Late collisions Duplex problem
detected
Duplex problem, EMI,
network extension
4 On Half duplex CRC error OK EMI
5 On Full duplex None OK
6 On Full duplex Collisions OK EMI
7 On Full duplex Late collisions OK EMI
8 On Full duplex CRC error OK EMI
9 Off Half duplex None OK
10 Off Half duplex Collisions OK
11 Off Half duplex Late collisions Duplex problem
detected
Duplex problem, EMI,
network extension
12 Off Half duplex CRC error OK EMI
13 Off Full duplex None OK
14 Off Full duplex Collisions OK EMI
15 Off Full duplex Late collisions OK EMI
16 Off Full duplex CRC error Duplex problem
detected
Duplex problem, EMI
Table 31: Evaluation of non-matching of the duplex mode

Table of Contents

Other manuals for Hirschmann MACH 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 4000 and is the answer not in the manual?

Hirschmann MACH 4000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 4000
CategoryNetwork Router
LanguageEnglish

Related product manuals