Loading...
The following table shows description of menu items in the window. Those
values cannot be changed.
Table 4-6 Controller properties submenu 1 items
Menu items Description
Global Hot spare for
Emergency
Whether or not to rebuild a different type of drive for global
hot spare
Unconfig Good for
Emergency
Whether or not to rebuild a different type of unconfigured
physical drive
Emergency for SMARTer Whether or not to apply SMART copy back to a different type
of physical drive for hotspare
Shield State Supported Diagnostics for physical drives by the disk array controller:
This item is ineffective regardless of the setting value
SSD Disk Cache Setting SSD cache setting value
Metadata Size Metadata size of the disk array controller
Tip: You cannot change the settings for those items displayed here.
Controller properties submenu 2
Click Next in the Controller properties submenu 1 window. The following
window is displayed.
The following table shows description of menu items in the window.
4-14
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide

Table of Contents