Status Displays the array status.
Bay Displays the device bay location.
Device Identifier Displays the device identifier.
RAID Disk Specifies the devices (disks) that make up an IM array. If RAID Disk is
Yes, the device is part of an IM array, if No, the device is not part of
an IM array. This field is grayed out under the following conditions:
• The device does not meet the minimum requirements for use in an
IM array.
• The device is not large enough to mirror data on the primary drive.
• This disk has been selected as the hot spare for the IM array.
Hot Spr Specifies whether a device is the hot spare for an IM array. If Hot
Spr is Yes, the device is used as a hot spare for the IM array. If Hot
Spr is No, the device is not used as a hot spare for the IM array. Only
one hot spare per IM array is permitted.
A hot spare is not required in an IM. A hot spare can be specified at
array creation, or after creation if the array uses 5 disks or fewer. This
field is grayed out under the following conditions:
• The device does not meet the minimum requirements for use in an
IM array.
• The array has a hot spare.
• The array is made up of the maximum number of devices (6).
• The device isn't large enough to mirror data on the primary drive.
The hot spare drive must be greater than or equal to the size of
any drive in the IM volume.
Drive Status Disk is online and fully functional.OK
Missing Disk is not responding.
Failed Disk has failed.
Initializing Disk is initializing.
CfgOffln Disk is offline at host's request.
User Fail Disk is marked failed at host's request.
Offline Disk is offline for some other reason.
Inactive Disk has been set to inactive.
Not Syncd Data on disk is not synchronized with the rest of
the array.
Primary Disk is the primary disk for a two-disk mirror and
is OK.
Secondary Disk is the secondary disk for a two-disk mirror
and is OK.
Wrg Type Device is not compatible for use as part of an IM
array.
Too Small Disk is too small to mirror data.
Max Dsks Maximum number of disks allowed for this type
of array has been reached or maximum number
of total IM disks on a controller has been reached.
Configuring the HP 2 Internal Port SAS Host Bus Adapter 63

Table of Contents

Other manuals for HP Integrity BL870c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL870c and is the answer not in the manual?

HP Integrity BL870c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL870c
CategoryServer
LanguageEnglish

Related product manuals