Missing Disk is not responding.
Failed Disk has failed.
Initializing Disk is initializing.
CfgOffln Disk is offline at host's request.
User Fail Disk is marked failed at host's request.
Offline Disk is offline for some other reason.
Inactive Disk has been set to inactive.
Not Syncd Data on disk is not synchronized with the rest of
the array.
Primary Disk is the primary disk for a 2 disk mirror and is
OK.
Secondary Disk is the secondary disk for a 2 disk mirror and
is OK.
Wrg Type Device is not compatible for use as part of an IM
array.
Too Small Disk is too small to mirror existing data.
Max Dsks Maximum number of disks allowed for this type
of array has been reached or maximum number
of total IM disks on a controller has been reached.
No SMART Disk doesn't support SMART and cannot be used
in a RAID array.
Wrg Intfc Device interface (SAS) differs from existing IM
disks.
Pred Fail Indicates whether device SMART is predicting device failure (Yes, No).
Size(MB) Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576 bytes). If the device is part of a two-disk array,
this field reflects the size of the array, not the size of the disks. If the
device is part of a three or more disk array, this field is the size of the
disk within the array.
When creating a striped array, the usable size of the array is
determined by the number of drives multiplied by the size of the smallest
drive in the array. In arrays consisting of different sized drives, excess
space on larger drives is unusable.
View Array Screen
The View Array screen enables you to view the current array configuration. To access the View
Array screen, press Enter on the View Existing Array field from the Select New Array Type screen.
You can perform the following actions on the View Array screen:
• To view the next array, press N.
• To create a new array, press C.
Following are descriptions for the View Array screen:
Array Displays the number of this array.
Identifier Displays the array identifier.
Type Displays the RAID type.
Scan Order Displays the array scan order.
Size (MB) Displays the array size.
62 Installing the Server Blade Into the Enclosure

Table of Contents

Other manuals for HP Integrity BL870c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL870c and is the answer not in the manual?

HP Integrity BL870c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL870c
CategoryServer
LanguageEnglish

Related product manuals