DescriptionCode
Linked-list next pointer is invalid.341Ch
CRAM transfer started but not finished.341Dh
Allocated insufficient CRAM.341Eh
Dataset is available in LM but the drive is not positioned to append.341Fh
Datasets in LM, Flush WITH_EOD required before the current operation3420h
LM flushed but EOD is required before the current operation.3421h
The specified dataset type is not supported by the operation.3422h
The specified CRAM dataset type is not supported.3423h
LF has attempted an operation away from EOD that can only be performed at EOD.3424h
Search dataset available dataset number does not match the DSIT contents.3425h
LF has requested a dataset while LM is changing to backup mode.3426h
Undefined error.37FFh
Logical pipeline control (from 3800h)
DescriptionError
No error. Synonymous with GOOD status.3800h
Aborted operation.3801h
Busy. An operation request was received while in a transient state.3802h
The value of a parameter received with a Logical Pipeline Control operation request falls
outside its valid range.
3803h
Received an operation request while in a mode that does not allow that operation.3804h
Operation aborted because of a write-behind error.3805h
Logical Pipeline Control has detected an unexpected File Mark during a Space operation.3806h
A non-specific error has occurred in Logical Pipeline Control.3BFFh
Mechanism control (from 3C00h)
DescriptionError
No error.3C00h
Aborted command error.3C01h