12V5V12V5VSpecification
24.36W17.90W24.37W17.86WMax transient power
150 mVpp150 mVpp150 mVpp150 mVppMax noise/ripple
Half-height drives
SAS DrivesFC Drives
12V5V12V5VSpecification
13.2V5.25V13.2V5.25VMax voltage
10.8V4.75V10.8V4.75VMin voltage
0.56A3.48A0.54A3.36AMax steady-state current
2.09A3.60A1.70A3.45AMax transient current
6.72W17.39W6.48W16.80WMax steady-state power
25.09W18.0W20.51W17.25WMax transient power
150 mVpp150 mVpp150 mVpp150 mVppMax noise/ripple
NOTE:
Half-height FC drive power consumption figures are currently provisional. Final power consumption
figures will be available in a future edition of this document.
Airflow requirements
HP LTO Ultrium drives require forced airflow to ensure that components never exceed critical
temperatures.
Full-height drives
Airflow should be from front to back. The required flow depends on the ambient air temperature:
6 cfm for ambient air temperatures fluctuating in the range 10°C35°C.
8 cfm for ambient air temperatures fluctuating in the range 10°C40°C.