DescriptionError
The PCA2 EEPROM is not supported on this platform.40D4h
An unknown KMS security parameter was asked for.40D5h
The KMS security parameter was encrypted, however the encrypted record size ends up
being too large for storage
40D6h
The Initialization check of the KMS security table showed a bad CRC on the directory entries.
The whole table must be cleared and rebuilt.
40D7h
The KMS Security table does not have an entry for the KMS security parameter requested
(tha is, it is not stored in the table).
40D8h
The Secure EEPROM storage will only allow encryption of field sizes divisible by 16, such
as 16, 32, 48 and so on.
40D9h
Operating system (from 4400h)
DescriptionError
‘vGiveSem’ failed to signal a semaphore.
4400h
Physical formatter (from 4C00h)
DescriptionError
C1 has finished before C2 is ready for the dataset.4C00h
The physical formatter has been sent an invalid configuration name.4C01h
The physical formatter has been sent an invalid configuration value4C02h
C2 hardware is busy. The physical formatter C2 hardware is currently processing a dataset.4C03h
The physical formatter C2 control DS0 register go bit is set.4C04h
The physical formatter C2 control DS1 register go bit is set.4C05h
The physical formatter C1 control register go bit is set.4C06h
The physical formatter CCQ Reader control register go bit is set.4C07h
The physical formatter Read Chain Controller control register go bit is set4C08h
The physical formatter has been asked for the error rate log for a channel which does not
exist
4C09h
The physical formatter has been asked for the error rate logs for a channel which does not
exist.
4C0Ah
The physical formatter could not set the callback timer to enable the Hyperion read gate.4C0Bh
Drive error codes110