Trace logger (from 6C00h)
DescriptionError
TraceLogger initialization failed. BMM returned no good.6C00h
The last Live Trace entry has been reached. Not an error.6C01h
The drive has insufficient resources to set more Live Traces.6C02h
A flush has started and the initiator must wait to receive the SDL signal diTraceLogFlushed.
6C03h
An operation has started but the caller must wait for the callback function to be executed.6C04h
Mechanical interface (from 7400h)
DescriptionError
No error.7400h
Aborted command.7401h
Unsupported command.7402h
Wrong number of parameters.7403h
Invalid parameter.7404h
This command is already in progress.7405h
This command is not allowed now.7406h
Command processing error.7407h
A DSP event has occurred (most likely an off-track event unless the default was changed).7408h
The command is obsolete.7409h
Incomplete initialization of the mechanism740Ah
There was a timing fault in the servo interrupt.740Bh
The mechanism type (SensorRev) specified in the mechanism EEPROM is either obsolete
or unsupported.
740Ch
Obsolete command 300C.740Dh
Obsolete command 300D.740Eh
Invalid task. The current task for the servo system is of an unknown type. This is most likely
caused by a firmware bug.
740Fh
A Load command is not allowed at this time.7410h
An Unload command is not allowed at this time.7411h
Drive error codes116