EasyManua.ls Logo

HP LTO Ultrium - Front Panel for Use in Autoloaders

HP LTO Ultrium
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Front panel for use in autoloaders
A special front panel is available for autoloader applications. The front panel fits within the drive form
factor in height and width:
2. Access hole for emergency reset switch1. Access to Eject button
4. Access to datum surfaces on the front of the drive3. LEDs
The autoloader front panel has the following features:
Simple one-piece plastic design
Pinhole access to the eject switch on the drive for manually ejecting a cartridge. Press this for ap-
proximately ten seconds to start a forced eject for recovering a cartridge manually. See Emer-
gency unload on page 61 for details.
Indicator LEDs provide a visible indicator of the state of health of the drive. See Other LED pat-
terns on page 23 for details. The LEDs are viewed through holes in the autoloader front panel;
no light pipes are present.
Clearance for picker finger access to the right-side cartridge-handling notch
Two square holes through the panel to provide access to a datum surface on the front of the drive
Cartridge lead-in features to improve cartridge load and unload operations
Volume 1: hardware integration 69