DescriptionCode
The Log Sense PC Code is in error.2C88h
Log Select: error in the parameter header.2C89h
Restart the Logical Pipeline after a format error.2C8Ah
The Buffer Manager has been interrupted with an error.2C8Eh
Check the cables. The Host Interface has exhausted all of the retries for a data phase.2C8Fh
Log Select parameter list length error.2C90h
hiPopulateSenseBuffer() could not find any free sense data buffers.
2C91h
The failure prediction threshold has been exceeded. This error code is sent when a check
condition is generated for a CDB as a result of the Test flag being set in the Information Ex-
ceptions Mode page.
2C92h
Reset after GE. Triggers the power-on self-test UA 2900 after LTO 1 SCSI ASIC GE has been
detected.
2C93h
Return GOOD status. Used to force GOOD status to be returned.2C94h
There is a firmware bug in the handling of an inquiry page.2C95h
There is a firmware bug in the execution of the Prevent/Allow Medium Removal com-
mand.
2C96h
There is a firmware bug in the parsing of a Mode page.2C97h
An attempt was made to write data or filemarks inside EW-EOM.2C98h
Firmware incorrectly programmed the SCSI macro.2C99h
An unsupported LUN was specified in the SCSI Identify message.2C9Ah
Aborting a previous command.2C9Bh
Aborting and no disconnect. A command was rejected that could not be queued while an
abort was in progress.
2C9Ch
The host interface has exhausted all of the retries for a command phase.2C9Dh
Parameter not supported. A request for an invalid page code has been sent.2C9Eh
Buffer offset good. This is used internally by the Read Write Buffer code and should never
be reported to the host.
2C9Fh
Operation in progress. Reported when an Immediate command is executing and a subsequent
command is received.
2CA0h
Illegal length record (ILI) too long, and there is an EOR in FIFO. This occurs when a record
is long by less than the FIFO length.
2CA1h
Illegal length record (ILI) too short with bad CRC.2CA2h
Illegal length record (ILI) too long with bad CRC.2CA3h
LUN not configured. The drive is the process of becoming ready.2CA4h