Page #21 background imageLoading...
Page #21 background image
Selecting RAID for fault toleranceSelecting RAID for fault tolerance
If your IT environment requires a high level of fault tolerance, select a RAID level that is optimized for fault tolerance.
This chart shows the relationship between the RAID level fault tolerance and the size of the storage array. The chart includes RAID 0, 5,
50, 10, 6, and 60. It also shows the percent reliability in increments between 1 and one billion and the storage array drive increments
between 0 and 96.
This chart assumes that two parity groups are used for RAID 50 and RAID 60.
This chart shows that:
RAID 10 is 30,000 times more reliable than RAID 0.
The fault tolerance of RAID 5, 50, 6, and 60 decreases as the array size increases.
Selecting RAID for fault tolerance 21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MR Gen10 Plus and is the answer not in the manual?

HP MR Gen10 Plus Specifications

General IconGeneral
Device TypeRAID Controller
InterfacePCIe 3.0 x8
RAID SupportYes
CategoryController
RAID Levels0, 1, 5, 6, 10, 50, 60
Memory2GB Flash-backed cache
StorageSAS/SATA
Power SupplyNot Applicable