Drive rebuildDrive rebuild
If a drive, which is configured as RAID 1, 5, 6, 10, 50, or 60 fails, the firmware automatically rebuilds the data on a spare or replacement
drive to prevent data loss. The rebuild is a fully automatic process. Monitor the progress of drive rebuilds in the Background Processes
in Progress window.
Access the drive rebuild rate by selecting Set Adjustable Task Rate under the More Actions menu then locating it under the Priority
Percentage column. Enter a number from 1 to 100. The higher the number, the faster the rebuild will occur (and the system I/O rate
might be slower as a result).