EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Hp_Deviceindication: Controller Status Changed to ERROR

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Array 110
4-4-8 HP_DeviceIndication: Controller Status Changed to
OK
Table 4-102 HP_DeviceIndication: Controller Status Changed to OK
Property name Property implementation
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-9 HP_DeviceIndication: Controller Status Changed to
ERROR
Table 4-103 HP_DeviceIndication: Controller Status Changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller status has changed to Error.
AlertingMangedElement WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions Check controller status and run diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller status Error
EventCategory 6 (Primary Storage)

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server