EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Hp_Deviceindication: Controller Redundancy Has Been Lost

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Array 115
4-4-11 HP_DeviceIndication: Controller Redundancy has
been lost
Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller has detected that redundancy
has been lost due to failure or loss of communication
with partner controller.
AlertingMangedElement WBEM Path to SMX_SAArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 4
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions Check status of the partner array controller.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller Redundancy has been lost
EventCategory 6 (Primary Storage)
ProbableCause 1 (other)
ProbableCauseDescription Array Controller Redundance has been lost
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication