EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Smx_Powersupplymodule

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Power Supply 296
10-3-11 SMX_PowerSupplyModule
SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply
numbers for existing instances do not change when other power supplies are added and removed.
Table 10-12
Class: SMX_PowerSupplyModule
Property name
Property implementation
CIM_ManagedElement
Caption Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
Description Descripton of ths power supply module including
ElementName type and status.
For example: elementname provides power for
powersupplytype. statusdescription.
where elementname represents the value of
ElementName,
powersupplytype represents the corresponding string
value of the PowerSupplyType enumeration and
statusdescription represents the value of
StatusDescriptions[0]
ElementName Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0] 2 (OK) if power supply is operating properly
3 (Dedgraded) if power supply is degraded
6 (Error) if power supply has failed
StatusDescriptions[0] Description of the status of the power supply
corresponding to the Opertational Status.
For example, Power Supply is operating properly if
OperationalStatus[0] is 2 (OK)
Power Supply is degraded if OperationalStatus is 3
(Degraded)
Power Supply has failed if OperationalStatus is 6
(Error)
HealthState 5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) if power supply has failed
Name Name of this power supply from the name displayed
by the MP or iLO and its location. For example, Power
Supply 1 at PowerSupplySlot=2 Power supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplyModule

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Related product manuals