System Power Supply 296
10-3-11 SMX_PowerSupplyModule
SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply
numbers for existing instances do not change when other power supplies are added and removed.
Table 10-12
Class: SMX_PowerSupplyModule
Property name
Property implementation
CIM_ManagedElement
Caption Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
Description Descripton of ths power supply module including
ElementName type and status.
For example: elementname provides power for
powersupplytype. statusdescription.
where elementname represents the value of
ElementName,
powersupplytype represents the corresponding string
value of the PowerSupplyType enumeration and
statusdescription represents the value of
StatusDescriptions[0]
ElementName Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0] 2 (OK) – if power supply is operating properly
3 (Dedgraded) – if power supply is degraded
6 (Error) – if power supply has failed
StatusDescriptions[0] Description of the status of the power supply
corresponding to the Opertational Status.
For example, Power Supply is operating properly – if
OperationalStatus[0] is 2 (OK)
Power Supply is degraded – if OperationalStatus is 3
(Degraded)
Power Supply has failed – if OperationalStatus is 6
(Error)
HealthState 5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) – if power supply has failed
Name Name of this power supply from the name displayed
by the MP or iLO and its location. For example, Power
Supply 1 at PowerSupplySlot=2 Power supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplyModule

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL280c - G6 Server and is the answer not in the manual?

HP ProLiant BL280c - G6 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL280c - G6 Server
CategorySoftware
LanguageEnglish

Related product manuals