EasyManuals Logo

HP ProLiant BL280c - G6 Server Datasheet

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #291 background imageLoading...
Page #291 background image
System Power Supply 291
Table 10-3 Class: SMX_PowerCollection
Property name
Property implementation
HP_GroupSystemSpecificCollection
GroupOperationalStatus[0] Represents the most severe power redundancy status
and non-fault tolerant power supply operational status:
0 (Unknown) —If power collection status is unknown
2 (OK) —If power supplies are operating properly
3 (Degraded) —If no
SMX_PowerSupply.OperationalStatus[0] for all non-
fault tolerant power supplies report 6 (Error) and
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 3 (Degraded
Redundancy) or 4 (Redundancy Lost) and no power
redundancy sets report 5 (Overall Failure).
6 (Error) —If SMX_PowerSupply.OperationalStatus[0]
for any non-fault tolerant power supplies report 6
(Error) or if
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 5 (Overall Failure).
Note: If the system starts up with a redundancy status
set to 4 (Redundancy Lost) and no power supplies have
been removed or failed, the GroupOperationalStatus
will be set to 2 (OK) because this is a valid
configuration.
GroupStatusDescriptions[0] Unknown status for power supplies, if
GroupOperationalStatus[0] is 0 (Unknown)
Power supplies are operating properly, if
GroupOperationalStatus[0] is 2 (OK)
Power supplies are degraded, if
GroupOperationalStatus[0] is 3 (Degraded)
Power supplies have failed, if
GroupOperationalStatus[0] is 6 (Error)
10-3-3 SMX_PowerRedundancySet
SMX_PowerRedundancySet is used to model power supply redundancy sets on Servers.
Table 10-4
Class: SMX_PowerRedundancySet
Property name Property implementation
CIM_ManagedElement
Caption Power Redundancy Set n, where n represents the
number of the redundancy set instance
Description Power Redundancy Set n is collection of fault tolerant
power supplies that provide redundant power.
n represents the number of the redundancy set instance
ElementName Power Redundancy Set n, where n represents the
number of the redundancy set instance

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL280c - G6 Server and is the answer not in the manual?

HP ProLiant BL280c - G6 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL280c - G6 Server
CategorySoftware
LanguageEnglish

Related product manuals