EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Hp_Deviceindication: Enclosure Power Supply Status Changed to Non Redundant

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Array 133
4-4-18 HP_DeviceIndication: Controller Cache status—
Permanently Disabled
Table 4-112 HP_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
Smart Array P400 Embedded Controller=7ā€ for
embedded controller where 7 is the internal identifier
for the embedded controller
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
VariableNames[] FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-19 HP_DeviceIndication: Enclosure Power Supply
status changed to Non Redundant
Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Related product manuals