PCI Device Provider 44
3-3-8 SMX_PCISlotLocation
SMX_PCISLotLocation is used to model PCI slot locations on HP Servers. The Windows specific
implementation class is SMX_PCISlotLocation.
Table 3-9
Class: SMX_PCISlotLocation
Property name
Property implementation
CIM_ManagedElement
Caption Same as ElementLocationTag.
Description Same as ElementLocationTag.
ElementName Same as ElementLocationTag.
CIM_Location
Name Unique identifier of the form:
HPQ:SMX_PCISlotLocation:<unique_id>
PhysicalPosition Opaque key.
Example for slot 6 in cabinet 1, bay 2 chassis 3:
01-02-03-FF-FF-06-FF-85
For Slot 2 in a non-cellular in this system:
FF-FF-FF-FF-FF-02-FF-85
HP_Location
ElementLocationTagDesc 0 (Hood Tag)
ElementLocationTag Text representing the controller location. Examples:
Cellular Servers
Slot <slot_number> in Cabinet=<cab> Bay=<bay>
Chassis=<chassis>
Blade Servers
Mezzanine: <slot_number> in Blade: <blade_num>
All other HP Servers
PCI Slot Loation Slot=<slot_number>
Or PCI Slot Location Mezzanine=<slot_number>
LocationInfoDesc for HP Integrity Cellular Servers Array of enumerated values describing context of
information at comparable index in
LocationInformation array 0, 1, 2, or 3.
LocationInfoDesc[0] per LocationInfornation[0].
Cellular Servers
3 (PCI Slot)
6 (Chassis)
2 (Interconnect Bay)
7 (Cabinet)