System Power Supply 289
• SMX_SystemPowerMeter
• SMX_AssociatedPowerMeter
10-3-1 SMX_PowerSupply
SMX_PowerSupply is used to model power supplies on Servers. Please note: power supply numbers
for existing instances do not change when other power supplies are added and removed.
Table 10-2
Class: HP_PowerSupply
CIM_ManagedElement
Caption Short description of this power supply from the name
displaed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
Description Description of this power supply, including
ElementName, PowerSupplyType and
StatusDescription[0] and StatusDescription[1].
For example: elementname provides power for
powersupplytype. statusdescription.
where elementname represents the value of
ElementName,
powersupplytype represents the corresponding string
value of the PowerSupplyType enumeration and
statusdescription represents the value of
StatusDescriptions[0] and StatusDescriptions[1]
ElementName Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
OperationalStatus[1] Power supply extended status value. See Profile.
StatusDescriptions[0] Description of the status of the power supply
corresponding to the OperationalStatus.
For example: Power Supply is operating properly– if
OperationalStatus[0] is 2 (OK);
Power Supply is degraded – if OperationalStatus[0] is
3 (Degraded)
Power Supply has failed – if OperationalStatus is 6
(Error)
StatusDescriptions[1] Power Supply Extended status description. See Profile.
HealthState 5 (OK)—if the power supply is operating properly
10 (Degraded) if power supply is degraded
20 (Major Failure)—if the power supply has failed