System Fan 285
9-4-8 HP_DeviceIndication: Fan Redundancy Lost
Table 9-28 HP_DeviceIndication: Fan Redundancy Lost
Property name
Property implementation
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the redundancy set where redundancy
was lost.
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
ProviderName HP Cooling
RecommendedActions Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
HP_AlertIndication
Summary Cooling redundancy has been lost
EventCategory
23 (System Cooling)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy has been Lost
9-4-9 HP_DeviceIndication: Fan Redundancy Restored
Table 9-29 HP_DeviceIndication: Fan Redundancy Restored
Property name Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description Cooling redundancy for the system has been restored.
(RedundancySetCaption), where
RedundancySetCaption is SMX_FanRedundancySet.
Caption of the cooling redundancy set with restored
redundancy
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the cooling redundancy set with restored
redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 8
ProviderName HP Cooling