SMX_SAS HBA Provider 212
Table 6-81 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
6-2-12 Enclosure Power Supply Status changed to Redundant
Degraded
Table 6-82 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication

Table of Contents