Smart Array 131
4-4-17 HP_DeviceIndication: Controller Cache status
Temporarily Disabled
Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
4-4-18 HP_DeviceIndication: Controller Cache status
Permanently Disabled
Table 4-112 HP_DeviceIndication: Controller Cache statusPermanently Disabled
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Permanently Disabled. Controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement WBEM path to the SMX_SAArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 11
EventTime Time of the event or time of the indication if event time
is unknown
ProviderName HP SmartArray
RecommendedActions Check Cache controller error code. Run diagnostics.
SystemName Name of the computer system generating the indication