System Fan 284
9-4-7 HP_DeviceIndication: Fan Redundancy Reduced
Table 9-27 HP_DeviceIndication: Fan Redundancy Reduced
Property name
Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A fault tolerant fan is no longer providing cooling for a
cooling redundancy set. (RedundancySetCaption),
where RedundancySetCaption represents the
SMX_FanRedundancySet.Caption for the redundancy
set with reduced redundancy.
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the redundancy set with reduced
redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 5
ProviderName HP Cooling
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary Cooling redundancy has been reduced
EventCategory
23 (System Cooling)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy has been Reduced
9-4-8 HP_DeviceIndication: Fan Redundancy Lost
Table 9-28 HP_DeviceIndication: Fan Redundancy Lost
Property name Property implementation
CIM_Indication
PerceivedSeverity 4 (Minor)
CIM_AlertIndication
Description Cooling redundancy has been lost.
(RedundancySetCaption), where
RedundancySetCaption represents the
SMX_FanRedundancySet. Caption for the redundancy
set that lost redundancy.

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL280c - G6 Server and is the answer not in the manual?

HP ProLiant BL280c - G6 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL280c - G6 Server
CategorySoftware
LanguageEnglish

Related product manuals