Smart Array 129
4-4-17 HP_DeviceIndication: Controller Cache status—
Temporarily Disabled
Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
Description Smart Array Controller Cache Status is set to a status of
Temporarily Disabled. This may be caused by a rebuild
or configuration change, normal operation will return
after background operations have completed.
AlertingMangedElement WBEM path to the SMX_SAArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
EventTime Time of the event or time of the indication if event time
is unknown
ProviderName HP SmartArray
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is set to Temporarily
Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Array Controller Cache Status Changed to Temporarily
Disabled
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0