Smart Array 128
4-4-16 HP_DeviceIndication: Controller Cache Status - OK
Table 4-110
HP_DeviceIndication: Controller Cache status changed to OK
Property name
Property implementation
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
Smart Array P400 Embedded Controller=7” for
embedded controller where 7 is the internal identifier
for the embedded controller
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
VariableNames[] FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string

Table of Contents