System Power Supply 304
Table 10-24 HP_DeviceIdentification: Power Supply Removed
Property name
Property implementation
CIM_AlertIndication
Description A power supply has been removed. (Power Supply),
where Power Supply is the system power supply that
was removed
AlertingManagedElement WBEM path of the SMX_WinPowerSupply instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Power
RecommendedActions Check the system power supply configuration. Verify
that this power supply was removed intentionally.
HP_AlertIndication
Summary Power Supply removed
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Supply Removed
10-4-3 HP_DeviceIndication: Power Supply Inserted
Table 10-25 HP_DeviceIndication: Power Supply Inserted
Property name
Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A power supply has been inserted.
PowerSupplyCaption), where PowerSupplyCaption is the
SMX_PowerSupply.Caption for the power supply that
has been inserted.
AlertingManagedElement WBEM path of the SMX_PowerSupply instance
representing the inserted power supply
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Power
RecommendedActions No action is recommended.
HP_AlertIndication

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL280c - G6 Server and is the answer not in the manual?

HP ProLiant BL280c - G6 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL280c - G6 Server
CategorySoftware
LanguageEnglish

Related product manuals