System Power Supply 308
10-4-7 HP_Device Indication: Power Supply Redundancy Reduced
Table 10-29 HP_DeviceIndication: Power Supply Redundancy Reduced
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy has been Reduced
10-4-8 HP_DeviceIndication: Power Supply Redundancy
Lost
Table 10-30 HP_DeviceIndication: Power Supply Redundancy Lost
Property name Property implementation
CIM_Indication
PerceivedSeverity 4 (Minor)
CIM_AlertIndication
Description Power redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set that lost redundancy.
AlertingManagedElement WBEM path of the SMX_WinPowerRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
ProviderName HP Power
RecommendedActions Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary.
HP_AlertIndication
Summary Power redundancy has been lost.
EventCategory 16 (System Power)
ProbableCause 88 (Loss of Redundancy)
Power Redundancy has been Lost