4-4-26 HP_DeviceIndication: Enclosure Fan status
changed to Degraded
Table 4-120
HP_DeviceIndication: Enclosure Fan status changed to Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
Description A Storage Enclosure Fan status changed to a status of
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 305
EventTime Time of the event or time of the indication if event time
unknown
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Fan Status changed to Degraded.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>