System Power Supply 307
10-4-6 HP_Device Indication: Power Supply Repaired
Table 10-28 HP_Device Indication: Power Supply Repaired
HP_AlertIndication
Summary PowerSupplyCaption has been repaired, where
PowerSupplyCaption is the HP_WinPowerSupply.
Caption for the power supply that has been repaired.
EventCategory 16 (System Power)
ProbableCauseDescription Power Supply Repaired
10-4-7 HP_Device Indication: Power Supply Redundancy Reduced
Table 10-29 HP_DeviceIndication: Power Supply Redundancy Reduced
Property name Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A fault tolerant power supply is no longer providing
power for a power redundancy set.
(RedundancySetCaption), where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the SMX_PowerRedundancySet
instance representing the redundancy set with reduced
redundancy.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 5
ProviderName HP Power