System Power Supply 309
10-4-9 HP_DeviceIndication: Power Supply Redundancy Failed
This indication is not supported on ProLiant systems since redundancy set failure, which is failure
beyond redundancy lost, will cause system shutdown.
Table 10-31
HP_DeviceIndication: Power SupplyRedundancy Failed
Property name
Property implementation
CIM_Indication
PerceivedSeverity 5 (Major)
CIM_AlertIndication
Description Power redundancy has been lost.
(RedundancySetCaption)where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set that failed redundancy.
AlertingManagedElement WBEM path of the SMX_PowerRedundancySet
instance representing the redundancy set where
redundancy failed
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
ProviderName HP Power
RecommendedActions Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary.
HP_AlertIndication
Summary
Power redundancy failed
EventCategory
16 (System Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy has failed
10-4-10 HP_DeviceIndication: Power Supply Redundancy
Restored
Table 10-32 HP_DeviceIndication: Power Supply Redundancy Restored
Property name
Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)