EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Hp_Deviceindication: Controller Battery Status Change - OK

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Array 119
4-4-12 HP_DeviceIndication: Controller Redundancy has
been restored
Table 4-106 HP_DeviceIndication: Controller Redundancy has been restored
Property name Property implementation
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
Smart Array P400 Embedded Controller=7” for
embedded controller where 7 is the internal identifier
for the embedded controller
HWManufacturer Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
VariableNames[] FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-13 HP_DeviceIndication: Controller Battery Status
Change - OK
Table 4-107 HP_DeviceIndication: Controller Battery Status Change - OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (info)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Battery Status has changed to a status
of OK.
AlertingMangedElement WBEM path to the SMX_SAArrayController class.

Table of Contents