Smart Array 64
4-3-19 SMX_SAStorageSetting
SMX_SAStorageSetting implements the HPSA_StorageSetting class and represents the current raid
configuration for a Storage Volume. There is one instance per Storage Volume.
Table 4-20
Class: SMX_SAStorageSetting (CIM_StorageSetting)
CIM_ManagedElement
ElementName RAID <n>, where <n> is the raid description
RAID 6
CIM_SettingData
InstanceID Opaque key
CIM_StorageSetting
ChangeableType 0 (Not Changeable)
DataRedundancyGoal 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DataRedundancyMax 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DataRedundancyMin 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DeltaReservationGoal 0
DeltaReservationMax 0
NoSinglePointOfFailure FALSE – RAID 0
TRUE – RAID 1+0, RAID 5, RAID 6
PackageRedundancyGoal 0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMax 0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMin 0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
HPSA_StorageSetting