Smart Array 132
4-4-18 HP_DeviceIndication: Controller Cache status—
Permanently Disabled
Table 4-112 HP_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is Permanently Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Array Controller Cache Status Changed to Permanently
Disabled
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name