Smart Array 134
4-4-19 HP_DeviceIndication: Enclosure Power Supply
status changed to Non Redundant
Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
IndicationTime Time of indication
Description Storage Enclosure Power Subsystem status has
changed to a Non Redundant Status
AlertingMangedElement WBEM path of the SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown
RecommendedActions Check status of all enclosure power supplies. Problem
may be caused by a failed power supply. Add or
replace power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply Status changed to Non-Redundant.
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication