Smart Array 138
4-4-21 HP_DeviceIndication: Enclosure Power Supply
status changed to Redundant Degraded
Table 4-115 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
IndicationIdentifier GUID string generated at indication
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem has changed to
Degraded Redundancy.
AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply Status changed to Redundant Degraded.
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power supply failure)
ProbableCauseDescription Redundant Power Supply Degraded
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication