Smart Array 142
4-4-23 HP_DeviceIndication: Enclosure Temperature
sensor status changed to Warning
Table 4-117 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
Description A Storage Enclosure Temperature sensor status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 308
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Verify that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor status changed to Warning
Condition.
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription Temperature Status Changed to Warning Condition
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>