System Temperature Sensor 324
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded
VariableValues SMX_NumericSensor UpperThresholdNonCritical,
UpperThresholdCritical, or UpperThresholdFatal
property value that is set for the temperature sensor
detecting the exceeded threshold
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A temperature sensor has detected that the temperature
has returned to a normal operating range.
(SensorCaption) where SensorCaption is the
SMX_NumericSensor.Caption for the temperature
sensor detecting a recovered exceeded threshold.
AlertingManagedElement WBEM path of the SMX_NumericSensor instance
representing the temperature sensor detecting a
recovered exceeded threshold
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown