System memory 331
Table 13-4 Class: SMX_MemoryModule
Property name
Property implementation
HealthState Enumerator indicating the memory module health state:
0 (Unknown), when OperationalStatus[0] = 0
(Unknown)
5 (OK), when OperationalStatus[0] = 2 (OK)
10 (Degraded/Warning), when OperationalStatus[0]
= 3 (Degraded)
Name Physical Memory Module Socket=y on
MemoryBoard=x,
where:
x is the board/cartridge number where the memory
module is located
y is the memory socket number where the memory
module is located
Physical Memory Module Socket=y on
ProcessorBoard=x, where:
x the processor board number where the memory
module is located
y is the memory socket number where the memory
module is located
CIM_PhysicalElement
CreationClassName SMX_MemoryModule
Tag HPQ:SMX_MemoryModule:x-y, where:
x is the cpu/board/cartridge number where the
memory module is located
y is the memory socket number where the memory
module is located
Description Physical Memory Module Socket=y on MemoryBoard=
x, where:
x is the board/cartridge number where the memory
module is located
y is the memory socket number where the memory
module is located
Physical Memory Module Socket=y on
ProcessorBoard=x, where:
x the processor board number where the memory
module is located
y is the memory socket number where the memory
module is located